Citizen PPU-231 Manual De Usuario

Descargar
Página de 100
PPU-231 User’s Manual
 
 31 
CITIZEN
 
7. SERIAL 
INTERFACE 
7.1 Specifications 
(1) Synchronous 
system 
: Asynchronous 
(2)  Baud rate 
:  1,200, 2,400, 4,800, 9,600, 19,200 bps (Selected by the user) 
(3) 1-word 
configuration 
 
Start bits 
:  1 bit 
 
Data bits 
:  8 bits or 7 bits (Setting upon shipment) 
 
Parity bits 
:  Odd, even, or no parity (Selected by the user) 
 
Stop bits 
:  1 bit or more 
(4) Signal 
polarity 
 RS-232C 
• Mark 
=  Logic "1" (-3 
∼ -12 V) 
• Space 
=  Logic "0" (+3 
∼ +12 V) 
(5)  Received data (RXD signal) 
• Mark 
=  1 
• Space 
=  0 
(6)  Reception control (DTR signal) 
• Mark 
:  Data not transferable 
• Space 
:  Data transferable   
(7)  Transmission control (TXD signal) 
• DC1 code(11H) X-ON 
:  Data receivable 
• DC3 code(13H) X-OFF 
:  Data not receivable 
 
7.2 
Connector's Pin Configuration 
No. Signal 
Name  Input/Output 
Function 
1 FG 
 
Frame 
Ground 
7 GND 
 
Signal 
Ground 
3 RXD 
Input 
Received 
Data 
20 
DTR 
Output 
Printer BUSY Signal 
2 TXD 
Output 
Transmitted 
Data 
DSR 
Input 
Data Set Ready 
 
 
 
 
 
[Note]  1.  The RS-232C signals are based on the EIA RS-232C.   
 
2.  The received data should be always maintained in the Mark status when no data is being 
transferred. 
Applicable connectors (D-Sub connectors) 
Printer side 
:  17LE-13250 (Anphenol) or its equivalent 
Cable side 
:  17JE-23250 (Anphenol) or its equivalent