Citizen Systems PMU2XXX Manual De Usuario

Descargar
Página de 312
 
- 111 - 
GS w n 
CT-S280 
CT-S300 
CT-S2000
CT-S4000
BD2-2220 
CT-S310 
support model 
PMU2XXX 
     
 
 
[Function]  
Specifying the horizontal size (magnification) of bar code
 
 
[Code] 
<
1D>H<77>H<n> 
 
[Range] 
2≦n≦6 
 
[Outline] 
[The specification which is common to the model]
 
Selecting bar code width.
 
 
[Default] n=3
 
 
[Sample Program]
 
 
LPRINT CHR$(&H1D);"h"; CHR$(30); 
LPRINT CHR$(&H1D);"w"; CHR$(2); 
GOSUB BC 
LPRINT CHR$(&H1D);"h"; CHR$(50);   
LPRINT CHR$(&H1D);"w"; CHR$(3); 
GOSUB BC 
LPRINT CHR$(&H1D);"h"; CHR$(80); 
LPRINT CHR$(&H1D);"w"; CHR$(4); 
GOSUB BC 
END 
BC: 
LPRINT CHR$(&H1D);"k"; 
LPRINT CHR$(4); 
LPRINT "12"; CHR$(0); 
RETURN 
 
[Print Results]
 
 
 
Height = 30, Magnification = 2
 
Height = 50, Magnification = 3
 
 
 
 
 
Height = 80, Magnification = 4