GS g 2 m nL nH 
CT-S280 CT-S300 CT-S2000
CT-S4000
BD2-2220 CT-S310 
support model 
PMU2XXX 
     
 
 
[Function] Sending 
maintenance 
counter
 
 
[Code] 
<
1D>H<67>H<32>H<m><nL><nH> 
 
[Range] m=0 
20≦(nL+nH×256)≦198 
nL=20、21、50、70、148、149、178、198 
nH=0 
 
[Outline] 
[The specification which is common to the model]
 
Send the maintenance counter value specified. 
nL, nH are used to set the maintenance counter number to (nL+nH×256). 
 
Counter Number 
Counter  Unit Counter 
Type 
Hex. Decimal 
14 20 
Paper-feed line[line] Resettable 
15 21 
Head powering count  [times] Resettable 
32 50 
Auto-cutter drive count  [times] Resettable 
46 70 
Product operation time[hours] Resettable 
94 148 
Paper-feed line[line] Accumulated 
95 149 
Head powering count  [times] Accumulated 
B2 178 
Auto-cutter drive count  [times] Accumulated 
C6 198 
Product operation time[hours] Accumulated 
 
• Configuration of data to be sent is shown below for the maintenance counter.
 
Hex. Decimal 
Data 
Count 
 
Header 
5FH 95 1 byte 
30H~39H 48~57 
Data 
1 - 10 bytes 
NUL 
00H 0 1 byte 
 
[Caution]
 
• During sending block data (maintenance counter value), real-time status and ASB status shall not 
be sent.    Thus, during sending the data, printer status can not be notified. 
• Counter value sent by this command is only a guideline value.    Due to an error occurrence and 
power off timing, figure data may have an error. 
• To update the flash memory, write the flash memory if any change occurs in the 
maintenance counter when the period where the printer is not in operation (printing, 
paper feeding, drawer, or cutting) lasts about 10 seconds, 2 minutes, and 1 hour. 
• If change occurs in each counter, data on RAM is updated correspondingly.