Citizen Systems BD2-2220 Manual De Usuario

Descargar
Página de 312
 
- 121 - 
fn=64  Function 64 Sending Key Code List of Defined NV Graphics 
GS ( L pL pH m fn d1 d2 
 
 
[Code] 
<
1D>H<28>H<4C>H<pL><pH><m><fn><d1><d2> 
 
[Range] (pL+pH×256)=4(pL=4、pH=0) 
m=48 
fn=64 
d1=75(“K”) 
d2=67(“C”) 
 
[Outline] 
[The specification which is common to the model]
 
Sends the key code list of defined NV graphics. 
• When key code list is present
   
Hex. 
Decimal 
Data Size 
 
Header 37H 
55 
byte 
Identifier 72H 
114 
byte 
Status 40Hor41H 
64or65 
byte 
Data 
30H~39H 
48~57 
2~ 80 bytes 
NUL 00H 
0  1 
byte 
 
• When key code is not present
 
Hex.
 
 
Decimal 
Data Size 
Header 37H 
55 
byte 
Identifier 72H 
114 
byte 
Data 40H 
64  1 
byte 
NUL 00H 
0  1 
byte 
 
When 40 or more key codes are present, they are sent by being divided in unit of 40max. 
• Status with continuous transmission data group is 41H. 
• Status without continuous transmission data group is 40H. 
 
After sending [Header - NUL], receives a response from the host and executes the next processing 
corresponding to the response. 
• In case of “Status (with continuous block): hexadecimal number = 41H / decimal number = 65” 
Response 
Content of Processing 
ASCII Decimal 
ACK 6 
 
Sends next data group. 
NAK 
21 
Resends previous data group. 
CAN 24 
Cancels 
processing. 
 
• In case of “Status (last block): hexadecimal number = 40H / decimal number = 64”
 
Response
 
Content of Processing
 
ASCII Decimal 
ACK 6 
Terminates processing. 
NAK 21 
Resends previous data group. 
CAN 24 
Cancels processing.