Citizen Systems BD2-2220 Manual De Usuario

Descargar
Página de 312
 
- 146 - 
GS C 1 n1 n2 n3 n4 n5 n6 
CT-S280 
CT-S300 
CT-S2000
CT-S4000
BD2-2220 
CT-S310 
support model 
PMU2XXX 
     
 
 
[Function] 
Setting the numbering counter mode (A)
 
 
[Code] 
<
1D>H<43>H<31>H<n1><n2><n3><n4><n5><n6> 
 
[Range] 
0≦n1、n2、n3、n4、n5、n6≦255 
 
[Outline] 
[The specification which is common to the model]
 
This command sets the numbering (serial number counter) mode.
 
n1+n2×256 (n1 = remainder, n2 = quotient): Counter default 
n3+n4×256 (n3 = remainder, n4 = quotient): Counter final value 
n5: Counter step value 
n6: Identical counter print counter 
(n1+n2×256) < (n3+n4×256): Count-up system 
(n1+n2×256) > (n3+n4×256): Count-down system 
(n1+n2×256) = (n3+n4×256) or n5 = 0 or n6 = 0: Counter stop 
 
[Default] n1+n2×256=1 
n3+n4×256=65535 
n5=1 
n6=1 
 
[See Also] 
 
[Sample Program]
 
LPRINT CHR$(&H1D);"C0";   
 
*CNT 
LPRINT CHR$(3); CHR$(0);   
 
  FOR I=1 TO 5 
LPRINT CHR$(&H1D);"C1";  
 
  LPRINT CHR$(&H1D);"c"; 
LPRINT CHR$(50); CHR$(0);  
 ¥ 
 
 NEXT I 
LPRINT CHR$(0); CHR$(0);    
 ¥ 
 LPRINT CHR$(&HA); 
LPRINT CHR$(5); CHR$(2);   
 
  RETURN 
GOUSAB *CNT   
LPRINT CHR$(&H1D);"C2"; 
LPRINT CHR$(5); CHR$(0); CHR$(10); 
GOUSAB *CNT 
END 
 
[Print Results]
 
When printing the counter value by setting a count-down range = 0 
to 50, step value = 5, repeat count = 2, and starting value = 50. 
 
50 45 40  
50 50 45 45 40  
5  
 
When printing the counter value by setting a count-down range to 0 
to 50, step value = 5, repeat count = 1, and starting value = 5, step 
cleared.