Citizen Systems BD2-2220 Manual De Usuario

Descargar
Página de 312
 
- 226 - 
ESC p m n1 n2 
CT-S280 
CT-S300 
CT-S2000
CT-S4000
BD2-2220 
CT-S310 
support model 
PMU2XXX 
     
 
 
[Function]  
Generating the specified pulses
 
 
[Code]     
<
1B>H<70>H<m><n1><n2> 
 
[Range]     
m=0、1、48、49 
0<n1≦n2≦255 
 
[Outline]  
[The specification which depend on the model]
 
• The signals specified by “n1” and “n2” are output to the connector pin specified by “m”. 
• “m” has the followings. 
 
m Connector 
Pin 
0, 48
Drawer kick-out pin No. 2 
1, 49
Drawer kick-out pin No. 5 
 
• The ON time is n1 x2 ms, and OFF time n2 x2 ms.
 
 
[Caution]
 
• When “m” is beyond a definition range, no signal is output, discarding “n1” and “n2”. 
• The drawer drive duty must be within the following range: 
 
ON time 
ON time+OFF time 
 0.2 
 
 
  (The OFF time should be 4 times or more longer than the ON time.)
 
 
 
[Sample Program]
 
LPRINT CHR$(&H1B) + "p" 
LPRINT CHR$(0);     
 
・・・・・
  Selects pin No. 2. 
LPRINT CHR$(5);     
 
・・・・・
  Sets ON time to 10 ms 
LPRINT CHR$(50);   
 
・・・・・
  Sets OFF time to 100 ms