5.3 Identification of Send Status 
 
Because the status sent from the printer has certain fixed bits, it is possible to identify to which command the status 
belongs. 
 
When using ASB (Automatic Status Back), however, the first byte of ASB should be checked, and then the three 
consecutive bytes except for XOFF should be treated as ASB data. 
 
Identification of Send Status
 
Command and Function   
Status 
GS  I 
0**0****>B 
GS  r 
0**0****>B 
XON 
00010001>B 
XOFF 
00010011>B 
DLE  EOT 
0**1**10>B 
ASB (1st byte)   
0**1**00>B 
ASB (2nd - 4th bytes)   
0**0****>B