Citizen Systems BD2-2220 Manual De Usuario

Descargar
Página de 312
 
- 75 - 
ESC 3 n 
CT-S280 
CT-S300 
CT-S2000
CT-S4000
BD2-2220 
CT-S310 
support model 
PMU2XXX 
     
 
 
[Function]  
Setting line feed rate of minimum pitch
 
 
[Code] 
<
1B>H<33>H<n> 
 
[Range] 
0≦n≦255 
 
[Outline]
 
[The specification which is common to the model]
 
Sets the line feed width per line to [n×basic calculation pitch] inches.
 
 
[Caution]
 
• The line feed width can be set separately for the STANDARD and PAGE MODES.
 
• The basic calculation pitch is set by GS P. Once defined, the line feed width is not changed if the 
basic calculation pitch is changed by GS P.
 
• Fractions resulting from calculation are corrected with the minimum pitch of the mechanism, and 
the remainder is omitted.
 
• In STANDARD MODE, this command uses the vertical (paper feed direction) basic calculation pitch 
(y). 
• In PAGE MODE, this command acts differently depending on the start point: 
(1) If the start point specified by ESC T is top left or bottom right, the command uses the vertical 
(paper feed direction) basic calculation pitch (y). 
(2) If the start point specified by ESC T is top right or bottom left, the command uses the 
horizontal (perpendicular to the paper feed direction) basic calculation pitch (x). 
• The maximum settable line feed width is 1016 mm (40 inches). A setting greater than this 
maximum is trimmed to the maximum. 
 
[Default]
 
CT-S300
/
CT-S280
/
BD2-2220
/
CT-S310
/
PMU2XXX
 
Approx. 4.23mm 
 
CT-S2000
/
CT-S4000
 
(1) When memory switch 5-2 is OFF: 
Approx. 4.23mm 
(2) When memory switch 5-2 is ON: 
Approx. 3.75 mm 
 