Citizen Systems CLP-521 Manual De Usuario

Descargar
Página de 54
Appendixes
48
Error
       Change in the status of a signal line
Both directions OFF
  Both directions ON
Paper end
Busy
: L
 H
Busy
: L 
 unchanged
PError : L
 H
PError : L
 H
Select : H
 L
Select : H 
 unchanged
nFault : H
 L
nFault : H
 L
Error other than paper end
Busy
: L
 H
Busy
: L 
 unchanged
• Head open
PError : L
 unchanged PError : L  unchanged
• Other
Select : H
 L
Select : H 
 unchanged
nFault : H
 L
nFault : H
 L
Conditions for Busy
• Receive buffer full
• Receive buffer full
• Data being read
• Data being read
• Error
Parallel port status signals when an error occurs
Under the specifications for this bi-directional parallel interface, the parallel
port status signals when an error occurs are, as shown below, partially
processed differently than with compatible mode used up till now. When
both are on in the setting menu, even if a printer error has occurred, the
BUSY signal line is not active (“H”).
Compatible timing specification
[When power is on] (Time it goes off-line)
[While receiving data]
Note: Busy rises when *Strobe signal starts, and data is latched with *Strobe
signal starts.
Data0-7 
*Strobe 
BUSY 
0.5
µ
0.5
µ
0.5
µ
Reset 
BUSY 
*ACK 
SELECT
 
PowerOn 
Interfaces