Printronix LQH-HWTM Manual De Usuario

Descargar
Página de 302
Reverse Print Errors
 273
104 
Dynamic BARCODE data field BFn not previously defined
Dynamic data field designated in the Execute Form mode was 
not defined in the Create Form mode. 
105
Dynamic ALPHA/BARCODE field number AFn/BFn error - 
must be 1-512
Dynamic alpha field number (AF
n) or bar code field number (BFn) 
must range from 1 through 512.
106
Not defined.
107
Dynamic ALPHA data field AFn not previously defined
The dynamic alpha field number called for was not previously 
defined in the Create Form mode.
108
Not defined.
109
Dynamic ALPHA/BARCODE field longer than previously 
defined
The BARCODE data provided exceeds the maximum length for 
the bar code selected. 
110
SFCC decimal input error - must be 1 - 255
The hexadecimal value on the ASCII chart for the Special 
Function Control Character is not valid. Refer to page 86 to select 
a valid SFCC.
Reverse Print Errors
111
REVERSE format error in input parameters
Re-enter the command with proper format.
112 
REVERSE starting row SR/ending row ER out of bounds
Exceeds the value specified to reverse the element.
113
REVERSE starting SC/ending column EC out of bounds
Exceeds the value specified to reverse the element.
114
Insufficient memory to store the REVERSE element
Insufficient memory space available for reversed print 
requirements.
115
PDF417 bar code sizing parameter illegal or too small for 
data
116
PDF417 security level has illegal value or format
117
Unusable or illegal raster data.
118
Unsupported raster image type.
119
Unsupported raster compression type.
120-121
Not defined.
122
EXECUTE form too wide for current page setting
The form was defined in one orientation while sent to print in 
another orientation. Use the debug slash (/) when creating a form 
to show which element is out of bounds (see page 314).