EVFU Example
 289
EVFU Example
The following EVFU example is a 2-inch form at 6 lpi line spacing. Thus, 12 
lines on the form must be defined. The form is repeated 3 times. Paper 
instructions are disabled.
Assign Line Identification Codes
Line ID Code
Description
Assigned Hex Code
Start Load
Start EVFU
1E
Line 1
Top of Form
10
Line 2 
Filler
11
Line 3
Filler
11
Line 4
Filler
11
Line 5
Vertical Tab
1B
Line 6
First channel stop
13
Line 7
Filler
11
Line 8
Filler
11
Line 9
Second channel stop
12
Line 10
Filler
11
Line 11
Third channel stop
15
Line 12
Filler
11
Stop Load
End EVFU
1F
EVFU Format in Execute Mode
The Execute command shown on the next page, derived from the Execute 
command format on page 59, illustrates how the EVFU data above is 
incorporated into the Execute command. All other Execute command 
parameters are shown in italics. (Optional parameters are shown in brackets 
[ ].) Figure 58 on page 291 illustrates the printed output from this data.
The boldface line below the EXECUTE command represents the hexadecimal 
EVFU load sequence which identifies the channel codes at which overlay 
data will be placed on each form. The example hex values correspond to the 
line identification codes listed above. Channel codes not described above as 
Filler channels are assigned unique hex codes. Calls to these channels will 
print overlay data at specific positions on the form.
The two ~AF lines, also shown in italics, represent the dynamic data. While 
the EVFU does not affect dynamic data positioning (data placement is defined 
by the ALPHA statement when the form was created), the commands are 
shown to specify where they would occur in relation to the EXECUTE 
command, the EVFU load sequence, and the overlay data.