Printronix LQH-HWTM Manual De Usuario

Descargar
Página de 302
Execute Form: Overlay Data
 67
RST
n
The optional incremental reset count parameter to 
specify the number of times an incremented field is 
printed (on one or more forms) before it is reset to 
the starting value. A reset count is useful when 
printing a hierarchy of fields where a low-level field 
generates a sequence of numbers, is reset, and the 
next higher field level is incremented (such as in a 
unit/box/carton application). To use the reset count 
parameter, enter RST and replace 
n with a number 
ranging from 1 through 65,535 to specify the reset 
count. The default reset count value is 0.
STARTDATA  Defines the starting value of the incrementing field. 
The maximum amount of STARTDATA characters 
must be equal to or less than the number of 
characters in the STEPMASK field. If the number of 
data characters in the Dynamic Alphanumeric Data 
command is less than the number used in 
STEPMASK, the data will print right justified with 
preceding spaces. (Leading spaces are not 
provided for bar code data.) For dynamic bar code 
data, the type of characters allowed for 
incrementing fields is based on the type of bar 
code. Refer to the individual bar code descriptions 
in the “Bar Codes” chapter for information on valid 
type and quantity of data characters. The 
STARTDATA must be enclosed within standard 
printable character delimiters just as a standard 
data field is enclosed within delimiters.
Execute Form: Overlay Data
Overlay data is variable alphanumeric data entered onto a predefined form. 
The form is completed by positioning the data in the exact location it will 
appear on the form when printed. The data is placed horizontally using tabs 
and spaces, and vertically using line feeds, form feeds, and the Electronic 
Vertical Format Unit (EVFU).
For example, if the serial number field on the form begins at character row 22 
and column 14, enter 22 line feeds, space over 14 columns, and input serial 
number overlay data. An entire form can be completed with a page of overlay 
data in this manner. Overlay data at the end of a form is printed on a new form 
until all overlay data is used. Then, to advance to the next form, use a form 
feed.
The IGP EVFU can be used to control vertical spacing of the overlay data. In 
place of line feed commands input individually, the EVFU can be programmed 
(during the Execute Form mode) to slew the overlay data to the 
predetermined line with a single command.