Write or Read RFID Format
57
and uses the value on the control panel’s 
LCD.
motion
Set this flag to 1 to program data into the 
tag without moving the label. The printer 
may adjust the label position while it 
writes data into the tag, but this 
adjustment will reverse before any 
subsequent normal label movement. 
Even if this flag is set to 1, other 
commands (i.e., alpha or barcode) may 
move the label.
protect
This flag indicates whether the data 
should be protected from being 
overwritten later. The default is 0, 
meaning the data are not protected. 
Other acceptable values are 1 to 255, 
meaning the data are protected using 
this number as the LOCK password.
data format
0 (ASCII) or 1 (hex). The default is 0.
reserved
This is a reserved flag. The PPI/ZGL 
absorbs this number.
Write or Read RFID Format
Purpose
This command allows you to write or read to an RFID 
tag.
Format
^RF
a,b,c,d
^RF
Write or Read RFID command.
a
Specifies the read or write option. The 
default is W.
W = write to the tag
L = write with LOCK
R = read the tag
b
Specifies the data format. The default is H.
A = ASCII
H = Hex
E = EPC format