Printronix SL5000r MP Manual De Usuario

Descargar
Página de 84
Chapter 2
Software Migration Tools (SMT)
66
UCC128 (64 bit) / UCC128_96 (96 bit): Copies data from a 
UCC-128 bar code with an application identifier (AI) in the 
range of 90-99 to an RFID tag. These AI’s are reserved for 
internal applications. The AI is not written to the RFID tag. Data 
written to the RFID tag is right justified and zero padded. 
Checksum data calculated by the printer is not encoded onto 
the tag. Bar code data beyond the 16th digit is truncated 
without an error message.
EAN8 (64 bit) / EAN8_96 (96 bit): Copies data from an EAN8 
bar code to an RFID tag. EAN 8+2 and EAN 8+5 variants are 
both supported. Data written to the RFID tag is right justified 
and zero padded. Checksum data calculated by the printer is 
not encoded onto the RFID tag.
EAN13 (64 bit) / EAN13_96 (96 bit): Copies data from an 
EAN13 bar code to an RFID tag. EAN 13+2 is also supported 
but EAN 13+5 variant is not supported. Data written to the RFID 
tag is right justified and zero padded. Checksum data 
calculated by the printer is not encoded onto the RFID tag.
UPC-A (64 bit) / UPC-A_96 (96 bit): Copies data from a UPC-
A, UPC-A+2 or UPC-A+5 bar code to an RFID tag. Data written 
to the RFID tag is right justified and zero padded. Checksum 
data calculated by the printer is not encoded onto the RFID tag.
EPC (64 bit) / EPC_96 (96 bit): This tool allows EPC data 
carried by a Code 3 of 9 bar code to be encoded onto an RFID 
tag. Data beyond the 16th digit is not allowable for an EPC and 
is truncated. Data must be numeric only.
zGTIN (64 bit) / zGTIN_96 (96 bit)zEPC (64 bit) / zEPC_96 
(96 bit)
zUCC128 (64 bit) / zUCC_96 (96 bit)zEAN8 (64 bit) 
/ zEAN8_96 (96 bit)
zEAN13 (64 bit) / zEAN13_9 (96 bit)
and zUPCA (64 bit) / zUPCA_96 (96 bit): These are all PPI/
ZGL emulation specific tools identical in function to those of 
their corresponding names above.
NOTE: SMTs are available only for RFID enabled printers. SMTs 
and CSTs are mutually exclusive: the loading of any CST 
will cause the SMTs to be ignored. For a description of 
CSTs, refer to the 
Remote Management Software 
Advanced Tool Kit User’s Manual.