Chapter 3
64 Bit And 96 Bit EPC Data Formats
74
IMPORTANT
When any of these three parameters are inconsistent then 
confusion is likely.
The following tables (Table 5 on page 74 for PGL and Table 6 on 
page 75 for ZGL) identify the consequences of mismatched criteria.
Table 5. PGL EPC Format Handling
EPC Format
(based on
header)
Selected 
Tag Data 
Length
Size of Data
Request (from
program)
Result
Comment
64 bit
64 bit
< 64 bit
OK
Pad 0s to left for 64 bit
64 bit
64 bit
= 64 bit
OK
As is
64 bit
64 bit
> 64 bit
Error
Data too long
64 bit
96 bit
< 64 bit
Read 96 bit
Pad 0s to left for 96 bit
64 bit
96 bit
= 64 bit
Read 96 bit
Pad 0s to left for 96 bit
64 bit
96 bit
64 bit <> 96 bit
Read 96 bit
Pad 0s to left for 96 bit
64 bit
96 bit
= 96 bit
Error
EPC incompatible with 
length
64 bit
96 bit
> 96 bit
Error
Data too long
96 bit
64 bit
< 64 bit
Error
EPC incompatible with 
length
96 bit
64 bit
= 64 bit
Error
EPC incompatible with 
length
96 bit
64 bit
> 64 bit
Error
Data too long
96 bit
96 bit
< 96 bit
OK
Pad 0s to left for 96 bit
96 bit
96 bit
= 96 bit
OK
As is
96 bit
96 bit
> 96 bit
Error
Data too long