Tech Service Replacement Schedule
Each time a service technician completes a level of preventive 
maintenance, he or she must reset the service level page count by 
selecting the Technician Service option on the Maintenance menu. 
This removes the maintenance error message.
The following actions should be performed by a service technician 
after the specified number of letter size pages (4% coverage) have 
been printed.
Item
Part #
Frequency
(Pages)
Action
Service
Level
Main charger
705741-001
300,000
Replace
D
Precharger
705742-001
300,000
Replace
D
Transfer charger
705742-001
300,000
Replace
D
Smoke filter
703540-001
300,000
Replace
D
Flash power supply filter
n/a
300,000
Clean
D
LED air filter
703543-001
600,000
Clean
E
Lamp housing filter
202838-001
600,000
Clean
E
Cleaning unit
705740-001
600,000
See Note 1
Replace
E
Transporting belt-3
703531-035
600,000
Replace
E
Xenon lamp
703541-001
900,000
Replace
F
Main charger
705741-001
1,200,000
Replace
G
Precharger
705742-001
1,200,000
Replace
G
Transfer charger
705743-001
1,200,000
Replace
G
Cleaning unit
705740-001
1,200,000
See Note 1
Replace
G
Lamp housing filter
202838-001
2,400,000
Replace
H