Printronix P7000 Manual De Usuario

Descargar
Página de 402
Chapter 4
HOST INTERFACE
92 
PI Ignored
The PI (Paper Instruction) signal is used to control vertical paper 
motion.
Enable (default). Ignores the PI signal and treats the data as 
characters or control codes.
Disable. Causes the printer to interpret the eight data lines as 
VFU commands when the PI signal is true.
Data Polarity
The Data Polarity parameter must be set to match the data polarity 
of your host computer. 
Standard (default). Does not expect the host computer to invert 
the data.
Inverted. Expects the data received on the data lines from the 
host computer to be inverted. Ones become zeros, and vice 
versa.
Resp. Polarity
The Resp. Polarity parameter must be set to match the response 
polarity of your host computer.
Standard (default). Does not invert the response signal.
Inverted. Inverts the response signal sent to the host 
computer.
Busy On Strobe
Enable (default). Asserts a busy signal after each character is 
received.
Disable. Asserts a busy signal only when the print buffers are 
full.
Latch Data On
Specifies whether the data is read on the leading or trailing edge of 
the data strobe signal.