Chapter 2
Saving The Configuration
38
3.
If necessary, press
↓ and ↵ at the same time to unlock the ↵
key.
4.
Press
↑ or ↓ until Gap/Mark Sensor / Disable* displays.
5.
Press
+
or
until Gap displays.
6.
Press
. An asterisk (*) displays next to Gap.
7.
Press
↓ until Auto Calibrate/Run Calibrate displays.
8.
Press
. Media advances until it can accurately detect the label
length indicators and then stops at the top-of-form position. The
sensed distance value then displays for one second.
9.
Auto Calibrate is successful when the sensed distance value
correctly matches that of the installed media. For the Gap
option, the sensed distance value is the physical length of one
label plus the length of one gap.
If GAP NOT DETECTED or PAPER OUT displays, check the
horizontal position of the media sensor (see “Positioning The
Media Sensors” on page 37)
, press PAUSE, and run Auto
Calibrate again.
10. Press the PAUSE key to take the printer offline.
11. Press the FEED key several times. Each time you press FEED,
the media should advance one label length and stop.
12. Once the sensed distance value and performance is confirmed,
save it to the desired configuration menu as described below
before powering off the printer.
Saving The Configuration
13. Press the
key until QUICK SETUP displays.
14. Press
↑ or ↓ until Save Config./1* displays.
15. Press
. Saving Configuration displays briefly.
..
.