Printronix T5000R Manual De Usuario

Descargar
Página de 102
Chapter 2
Operation
74
Operation
There are a number of factors which contribute to successful bar 
code validation, including printer speed, on-demand print settings, 
calibration, and ambient light. The following sections describe how 
to ensure your bar code validator is scanning and reporting 
properly.
Print Speed Limits
Two factors in the validation process affect the printer’s speed limit: 
minimum code height (bar code height) and minimum code gap. 
The printer automatically examines the Min. Code Height and Min. 
Code Gap values and sets the defined maximum slew (vertical 
paper movement) and print speeds to insure proper operation. If 
the current Print Speed and/or Slew Speed values in the MEDIA 
CONTROL menu are higher than the newly defined maximum, the 
values are changed to equal the maximum. If the current values are 
lower than the newly defined maximum, no change in speed 
occurs.
Min. Code Height (Bar Code Height)
The validator cannot function at the highest speed possible by the 
printer. It requires a minimum number of scans per bar code to 
make a reliable assessment, so the speed of the printer is limited 
by the height of the bar code. If the bar code is very short, printing 
needs to be slowed down to allow sufficient scans to occur. If the 
print speed exceeds this limit, the message Speed Exceeds 
Validator Limit will display. Print speed will be lowered automatically 
if required, but will not automatically reset to a higher speed.
The printer cannot predict how high all the bar codes in a given job 
will be, so it cannot automatically limit or adjust the print speed to 
insure the code height/speed requirement is being met. When the 
bar code is too short for the selected speed, the printer produces a 
missing bar code error condition. Therefore, printer speed must be 
set manually to compensate for bar code height.