M-S Cash Drawer 7193 Manual De Usuario

Descargar
Página de 118
7193 Owner’s Guide
Commands
May 1996
Recognizing Data from the Printer
An application sending various Real Time and non-Real Time commands to
which the printer responds can determine which command a response belongs to
by the following table. Responses to ESC u and ESC v are non-Real Time
responses and will arrive in the order in which they were solicited.
Note also that although the original intent of the response to ESC  v was to
provide error information in its one-byte response, the response up to now has
always been Hex 00 when transmitted. This is because ESC v was not processed
until the error condition was cleared. With the improvement to the busy line
handling described earlier in this section, ESC v will be processed as long as there
is not an error condition caused by trying to print with no paper or with the
cover open.
ESC u 0
0
0
0
0
0
0
x
x
Binary
ESC v
0
0
0
0
0
x
x
x
Binary
GS EOT n
0
x
x
1
x
x
1
0
Binary
DLE EOT n
0
x
x
1
x
x
1
0
Binary
GS  ENQ
1
x
x
x
x
x
x
x
Binary
XON
0
0
0
1
0
0
0
1
Binary
XOFF
0
0
0
1
0
0
1
1
Binary