Diagnostic Information
2-1
24xx
2.  Diagnostic Information
Start
Make a quick visual check for defects (loose or broken parts, 
unplugged connectors, paper jams, and so on).
Voltage, Ground, And Continuity Readings
Voltage Readings
All DC voltages must be within +5% through -10% of the values to 
be considered correct. Unless stated otherwise, all connectors 
should be connected normally when a voltage measurement is 
performed.
When a “Line Voltage” measurement is to be performed, the voltage 
on United States and Canada printers should be between 100 V ac 
and 127 V ac. On World Trade printers, the voltage is according to 
each country’s specification.
Ground Checks
To check for a correct ground, measure the voltage between the 
ground and a known good voltage source. The voltage 
measurement must be the same as the source voltage to consider 
that the ground is correct. Continuity measurements may be used to 
check grounds, however, be sure to measure to a known good 
ground using the lowest ohms scale and check for zero ohms.
CAUTION: Always unplug the power cord before doing any 
continuity measurement.
Continuity Readings
When measuring continuity, be sure no back circuits affect the 
measurement. If necessary, unplug connectors to remove any back 
circuits. Zero the ohm range on the lowest scale (X1). An open 
circuit will read infinity. A circuit with correct continuity will read zero 
ohms.