Zebra Technologies 105SL Manual De Usuario

Descargar
Página de 130
44
105SL User Guide
6/4/2004 11342L Rev. 8
Configuration
Password-Protected Parameters
Password-Protected Parameters
Certain parameters are password-protected by factory default, including the communication 
parameters.
The first attempt to change a password-protected parameter (pressing the plus (+) or minus (–) 
key) requires you to enter a four-digit password at the 
ENTER PASSWORD
 display. The (–) 
key changes the selected digit position; the (+) key increases the selected digit value. After 
entering the password, press 
NEXT/SAVE
. The parameter you wish to change is displayed. 
If the password was entered correctly, you can now change the value.
The first time that you attempt to change a password-protected parameter, the printer displays 
ENTER PASSWORD
. Before you can change the parameter, you must enter the four-digit 
password. After you have entered the password correctly, you do not have to enter it again 
unless you leave Setup Mode by pressing 
SETUP/EXIT
 or by turning the printer Off (O).
To Enter a Password for a Password-Protected Parameter, complete 
these steps:
1.
At the password prompt, use the (–) key to change the selected digit position.
2.
When you have selected the digit that you wish to change, use the (+) key to increase the 
selected digit value. Repeat these two steps for each digit of the password.
3.
After entering the password, press 
NEXT/SAVE
.
The parameter you selected to change is displayed. If the password was entered correctly, 
you can change the value.
Default Password Value
The default password value is 1234. The password can be changed using the ^KP (Define 
Password) ZPL II instruction or through ZebraLink
 
WebView (ZebraNet
®
PrintServer II or 
Wireless Print Server required).
Disable the Password Protection Feature
You can disable the password protection feature so that it no longer prompts you for a 
password by setting the password to 0000 via the ^KPØ ZPL/ZPL II command. To reenable 
the password-protection feature, send the ZPL/ZPL II command ^KPx, where x can be any 
number from 1 to 9999.
Note • 