Zebra Technologies 105Se Manual De Usuario

Descargar
Página de 110
Zebra S-Series User’s Guide
31
3$86(.H\6HOI7HVW
This self test is actually comprised of four individual test features, as 
described below.
1. The initial self test prints 15 labels at speed “A” then automatically 
PAUSES the printer.  When the PAUSE key is pressed, an additional 
15 labels print out.
2. While the printer is PAUSED, pressing the CANCEL key once alters 
the self test.  When the PAUSE key is pressed, the printer prints 15 
labels at speed “D” (“C” for the 300 dpi ).
3. While the printer is PAUSED, pressing the CANCEL key a second 
time alters the self test again.  When the PAUSE key is pressed, the 
printer prints 50 labels at speed “A.”
4. While the printer is PAUSED, pressing the CANCEL key once alters 
the self test a third time.  When the PAUSE key is pressed, the printer 
prints 50 labels at speed “D” (“C” for the 300 dpi ).
Note:   On printers with either the rewind or peel option installed, the 
peel mode is activated during the first half (steps 1–4) of the 
PAUSE Key Self Test.  On printers with a rewind option, the 
rewind plate must be removed for proper function of the peel 
sensors during the test.  The first label to print says, “PEEL 
OPTION INSTALLED.”  Each label must be manually removed 
from the sensor path before the next label prints.  Steps 1–4 are 
then repeated in rewind mode.
This self test can be used to provide the test printouts required when 
making adjustments to the printer’s mechanical assemblies.  See the 
sample printout in Figure 13.
Figure 13