Mitsubishi Electronics FT8600 220Ra Manual De Usuario

Descargar
Página de 279
150
SCSI Device Configuration
SCSI Device ID 
#0
#1
#2
#3
#4
#5
#6
#7
Sync Transfer Rate (MB/Sec)
320
320
320
320
320
320
320
320
Packetiged
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
QAS
No
No
No
No
No
No
No
No
Initiate Wide Negotiation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Enable Disconnection
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Send Start Unit Command
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
BIOS Multiple LUN Support
No
No
No
No
No
No
No
No
Include in BIOS Scan
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SCSI Device ID
#8
#9
#10
#11
#12
#13
#14
#15
Sync Transfer Rate (MB/Sec)
320
320
320
320
320
320
320
320
Packetiged
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
QAS
No
No
No
No
No
No
No
No
Initiate Wide Negotiation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Enable Disconnection
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Send Start Unit Command
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Enable Write Back Cache
N/C
N/C
N/C
N/C
N/C
N/C
N/C
N/C
BIOS Multiple LUN Support
No
No
No
No
No
No
No
No
Include in BIOS Scan
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
次にメニューとパラメータを説明します。ここでの説明を参照して最適な状態に設定してく
ださい。
SCSI Bus Interface Definitions
キーボードのカーソル
(<↓>キー/<↑>キー)を使って項目を選択します。それぞれの機能と
パラメータは次の表のとおりです。
項 目
パラメータ
機能/設定
SCSI Controller ID
0∼[7]∼15
「7」に設定してください。
SCSI Controller Parity
[Enabled]
「Enabled」に設定してください。
Disabled
SCSI Controller Termination
[Automatic]
終端抵抗の自動/有効/無効を設定しま
Enabled
す。「Automatic」に設定してください。
Disabled
[
]: 出荷時の設定
Additional Options
キーボードのカーソル(<↓>キー/<↑>キー)を使って項目を選択します。
ⓦ Boot Device Configurations
「Boot Device Configurations」にカーソルを合わせて<Enter>キーを押すと次のような
表示に変わります。
Boot Device Configuration
Single Image.
Master SCSI Controller ........................................ AIC-7092 A at alot 00 : 09 : 00
ⓦ SCSI Device Configuration
「SCSI Device Configuration」にカーソルを合わせて<Enter>キーを押すと次のような
表示に変わります。