Siemens 620 Manual De Usuario

Descargar
Página de 216
Hardware Information
7-27
SIMATIC Box PC 620  Manual
A5E00131465-01
Port to the Floppy Disk Drive
This port is intended for the connection of a notebook floppy disk drive. The
maximum connection length of the data cable may not exceed 40cm.
Pin no.
Designation
Description
Input/Output
1
P5V
+5V
Output
2
INDEX_N
Index hole recognition
Input
3
P5V
+5V
Output
4
DS_N0
Drive 0 selection
Output
5
P5V
+5V
Output
6
DCHG_N
Disk change display
Input
7
n.c.
not connected
-
8
n.c.
not connected
-
9
Reserved
reserved
-
10
MOT_N0
Activate motor 0
Output
11
Reserved
reserved
-
12
DIR_SL_N
Step motor direction
Output
13
n.c.
not connected
-
14
STEP_N
Step motor pulse
15
GND
Ground
-
16
WR_DAT_N
Write data signal
Output
17
GND
Ground
-
18
WR_GAT_N
Enable data signal
Output
19
Reserved
reserved
-
20
TRACK_N0
Track 0 signal
Input
21
Reserved
reserved
-
22
WR_PRT_N
Write protection signal
Input
23
GND
Ground
-
24
RD_DAT_N
Read Data signal
Input
25
GND
Ground
-
26
SIDE_1_N
Page selection
Output
Assignment of the IDE Ports
The primary IDE port is intended for the alternative installation of
2.5” and 3.5” hard disks. 3.5” drives are connected via a 40 pin 2.54mm latching
connector, 2.5” drives via a 44 pin 2mm latching connector. The two connectors
are connected in parallel. The secondary IDE port is intended for the optional
connection of a CD ROM and / or an LS 240 drive. It is adaptable via a 44 pin
2mm latching connector. The maximum connection length of the data cables may
not exceed 40cm.