Electromagnetic Compatibility 
Release 11/02 
4–2 
SIMATIC Panel PC 670/870 Start-Up Instructions 
  
 
Sinusoidal wave interference 
RF Radiation complying with EN 61000-4-3 
• 
Electromagnetic RF field, amplitude-modulated 
from 80–1000 MHz 
10 V/m 
80 % AM (1 kHz) 
• 
Electromagnetic RF field, pulse-modulated 
900 
±
 5 MHz  
10 V/m 
50 % ED 
200 Hz pulse repetition frequency 
• 
RF interference on signal lines, data lines, etc. complying with EN 61000-4-6, 
radio frequency, asymmetric, amplitude-modulated 
from 0.15 –80 MHz 
10 V RMS value 
80 % AM (1 kHz) 
Interference emission 
Radiated interference of electromagnetic fields according to 
EN 55011: Limit Value Class A, Group 1. 
from 30–230 MHz 
< 30 dB (µV/m)Q 
from 230–1000 MHz 
< 37 dB (µV/m)Q 
measured from a 30 m distance 
 
Radiated interference from mains AC line power supply complying with EN 55011: 
Limit Value Class A, Group 1 (only 230 V operating units) 
from 0.15–0.5 MHz 
< 79 dB (µV)Q 
< 66 dB (µV)A 
from 0.5–5 MHz 
< 73 dB (µV)Q 
< 60 dB (µV)A 
from 5–30 MHz 
< 73 dB (µV)Q 
< 60 dB (µV)A