3.3  Check of the RAID configuration 
3  Tests and Diagnostics
TECRA S3 Maintenance Manual (960-532)
[CONFIDENTIAL]
3-15
NO DRIVE for one drive is displayed
When “NO DORIVE” is displayed and the HDD is connected to the port, follow the
procedures below to check the HDD failure. When the HDD is not connected to the
port, removing of the drive causes the failure. It is not necessary to repair.
(1)  Install a new HDD.
When “NO DORIVE” is still displayed, It is judged that the MB or cable fails.
(2)  When a new HDD is recognized, It is judged that the HDD removed is failed.
Specify the reason by using the Independent Utility.
TOSHIBA RAID / RAID Information Display  Rev xx.xx.xxxx
Copyright(c) 2005 TOSHIBA CORPORATION. All Rights Reserved.
    Level    Status     Capacity
LD0 RAID-1  DEGRADE 
  xxGB
    Write cache        : Enable
    MBR Protection     : Disable
    S.M.A.R.T          : Enable
Port  Assgn Status   Size   Model               Rev
  0   LD0-0 ONLINE   xxGB  FUJITSU----------    xxxxxxx
  1         NODRIVE  xxGB  FUJITSU----------    xxxxxxx
< RAID : not OPTIMAL >