3.4  System Test 
3 Tests and Diagnostics 
Subtest 10 
CPU Temperature 
This subtest checks the CPU temperature. 
When the subtest starts, the following message appears on the display.  Enter 
the ambient Celsius temperature. 
EXT. TEMP = 
When the temperature is entered, test program turns off the screen message. 
After 15 minutes, it measures the CPU temperature and judges the test result 
(OK or NG) based on the gap between the ambient temperature and the 
measured temperature (threshold value). 
When any error occurs, an error log is written into “DIAGNOSTIC MENU: 5-
LOG UTILITIES”. 
The meaning of “WD” or “RD” of the error log is as follows: 
WD  : Reference value of CPU temperature rising (hexadecimal form)  
RD  : Gap between the CPU temperature and the ambient temperature 
(hexadecimal form). 
 
Subtest 11 
Wake Up Check 
Set “Wake-up LAN” to “Enabled” in the SETUP menu and restart the 
computer. Make sure the computer starts without fail.  
Satellite A10/TECRA A10/Satellite Pro A10  Maintenance Manual (960-445) 