Isolated Remote Analog Interface Operation 
DLM 600W Series  
2-2 
M51A Option 
2.1.1 
2.2 
INTFC SETUP Switch Functions 
 
The following sections describe the functions of the various switch positions: 
 
V, 10V or 4-20mA Select: Position-1, when ON, selects 0-10VDC programming of the output 
voltage.  Also, must be set to ON position when the ISOLATED ANALOG INTERFACE 
connector is wired for 4-20mA output voltage programming.  When OFF, selects 0-5VDC 
programming of the output voltage.   
 
I, 10V or 4-20mA Select: Position-2, when ON, selects 0-10VDC programming of the output 
current.  Also, must be set to ON position when the ISOLATED ANALOG INTERFACE 
connector is wired for 4-20mA output current programming.  When OFF, selects 0-5VDC 
programming of the output current.   
 
OVP, 10V Select:  Position-3, when ON, selects 0-10VDC programming of OVP threshold.  
When OFF, selects 0-5VDC programming of OVP threshold. 
 
VMON, 10V Select: Position-4, when ON, selects 0-10VDC range for readback of output 
voltage.  When OFF, selects 0-5VDC readback of output voltage.  Also, must be set to OFF 
position when the ISOLATED ANALOG INTERFACE connector is wired for 4-20mA output 
voltage readback. 
 
IMON, 10V Select: Position-5, when ON, selects 0-10VDC range for readback of output current.  
When OFF, selects 0-5VDC readback of output current.  Also, must be set to OFF position 
when the ISOLATED ANALOG INTERFACE connector is wired for  
4-20mA output current readback. 
 
EXT-OFF, Active-Low Select: Position-6, when ON, selects the ACTIVE-LOW logic level for 
disabling the output with the EXTERNAL-OFF signal of the ISOLATED ANALOG INTERFACE 
connector.  When OFF, selects the ACTIVE-HIGH logic level for disabling the output with the 
EXTERNAL-OFF signal of the Isolated Analog Interface connector.  
 
LCK-OUT: Position-7, when ON, disables the front panel controls; the front panel 
LOCAL(REMOTE) switch will not toggle between the front panel and remote control. 
 
Position-8: Not used 
 
SETUP 
Switch 
Only two positions of the SETUP switch remain functional:  Position-1, REM SNS, for remote 
sensing selection; Position-2, SLAVE, for master/slave selection.  Their operation is the same 
as presented in the Operation Manual.  The other switch positions, Position-3 through 
Position-8, are not used.