SECTION 1
1.1 Introduction 
1.2 
 
 M51A OPTION OVERVIEW 
This addendum is to be used in conjunction with the DLM 600W Series Power Supplies 
Operation Manual, 
Sorensen Document No. M362161-01. 
The Sorensen M51A Option for the DLM 600W Series power supplies provides a remote analog 
interface, which has safety isolation from the output terminals.  This allows the remote analog 
interface to be connected to user accessible (SELV) control circuits, even though the output 
terminals were floated at a high potential with respect to the chassis. 
General Description  
The M51A Option provides isolation for all programming, monitoring, and digital I/O signals that 
are available through the remote analog interface.  This isolation barrier eliminates the 
connection that exists in the standard DLM models between the non-isolated remote interface 
circuits and the output return (negative) terminal.  The M51A Option remote analog signals are 
referenced to chassis, and could be user accessible irrespective of the float potentials that exist 
at the output terminals. 
The M51A Option provides a full complement of programming, monitoring, and control methods.  
Remote programming is available for output voltage, current, and overvoltage protection (OVP).  
Analog output monitor signals are available for the output voltage and current.  Digital I/O 
signals provide indication of the operational state, and a means of enabling the remote interface 
and the output. 
The type and range of the control and monitor signals are user-selectable with a rear panel 
setup switch.   The output voltage, current, and OVP could be programmed with a 0-5VDC, 
0-10VDC, or 0-5kΩ resistance; in addition, the output voltage and current could be programmed 
with 4-20mA signals.  The output voltage and current monitors could produce 0-5VDC, 
0-10VDC, or 4-20mA signals.  Isolated 1mA current sources are provided to facilitate the 
utilization of 0-5kΩ programming resistances. 
Except for the isolated remote analog interface, the installation and operation of the DLM 600W 
Series power supplies remains as presented in the Operation Manual.  The following sections 
provide a detailed description of the new features and the differences in operation. 
M51A Option 
1-1