Siemens 440 Manual De Usuario

Descargar
Página de 78
6  Commissioning 
Issue 10/06 
 
MICROMASTER 440 
66 
Operating Instructions (Compact) 
6.4.18.10  Positioning down ramp 
 
Technological application 
Selects technological application. Sets control mode (P1300). 
 0  Constant torque 
  1  Pumps and fans 
 3  Simple Positioning 
 
Gearbox ratio input 
Defines the ratio between number of motor shaft revolutions to equal one revolution of the 
gearbox output shaft. 
n
n
Motor
Load
Load
Ü
Ü =
P2482
P2481
 
=
Motor revolutions
Load revolutions
Motor
Gear
 
 
Gearbox ratio output 
Defines the ratio between number of motor shaft revolutions to equal one revolution of the 
gearbox output shaft. 
 
No. of shaft turns = 1 Unit 
Sets the number of rotations of the motor shaft required to represent 1 unit of user 
selected units. 
=
=
s
U
P2484
Load
Mo
tor
Pulley radius r
No. of revolutions
1 [unit]
U
Distance s
 
 
Distance / No. of revolutions 
Sets the required distance or number of revolutions (see P2484). 
Motor
Gear
f
=
=
2
1
 
 
P2488
 
 
s
t
OFF1
f
 OFF1
 
.
 t 
P2488
.
t
P2488
f
OFF1
 
 
1.00 
P0500 = ... 
P2481 = ... 
1.00 
P2482 = ... 
1.00 
P2484 = ... 
1.00 
P2488 = ...