6.4.19 Data 
sets 
For many applications it is beneficial to have the possibility to change several 
parameter settings simultaneous during operation or in the state ready to run with 
an external signal. By indexing it is possible to set a parameter to several values 
which can be activated by data set change-over. There are the following data sets:  
¾
  CDS Command Data Set  
¾
  DDS Drive Data Set 
Command data set (CDS) 
 
P0810 =... 
 
Command data set CDS bit 0 (local / remote) 
Selects the command source in which bit 0 should be read-out to select a command data 
set (CDS). 
t
0
1
2
3
(0:0)
BI: CDS b0 loc/rem
P0810
(0:0)
BI: CDS bit 1
P0811
t
0
1
2
3
CO/BO: Act CtrlWd2
r0055
r0055
CO/BO: Act CtrlWd1
r0054
r0054
.15
.15
.15
.15
r0050
Active CDS
Selecting CDS
approx. 4 ms
approx. 4 ms
r0050
CO: Active CDS
Changeover time
Changeover time
 
The currently active command data set (CDS) is displayed using parameter r0050. 
 
P0811 =... 
 
BI: CDS bit 1 
Selects command source from which to read Bit 1 for selecting a command data set 
(see P0810). 
 
Example for CDS changeover: 
CDS1: Command source via terminals and setpoint source via analog input (ADC) 
CDS2: Command source via BOP and setpoint source via MOP 
CDS changeover is realized using digital input 4 (DIN 4) 
Steps: 
1.  Carry-out commissioning for CDS1 (P0700[0] = 2 and P1000[0] = 2) 
2.  Connect P0810 (P0811 if required) to the CDS changeover source  
(P0704[0] = 99, P0810 = 722.3) 
3.  Copy from CDS1 to CDS2 (P0809[0] = 0, P0809[1] = 1, P0809[2] = 2) 
4.  Adapt CDS2 parameters (P0700[1] = 1 and P1000[1] = 1) 
 
DIN4
Terminals
Sequence control
BOP
P0700[0] = 2
P0700[1] = 1
P0810 = 722.3
ADC
Setpoint
channel
MOP
0
1
P1000[0] = 2
P1000[1] = 1
Motor
control
0
1
 
0