B–14
976-0043-01-02
26D 24-hr Start Volts DC
10.0 to 35.5
24.6
20.0 to 71.0
49.2
26E 2-hr Start Volts DC
10.0 to 35.5
23.6
20.0 to 71.0
47.2
26F 15-min Start Volts DC
10.0 to 35.5
22.6
20.0 to 71.0
45.2
26G Read LBCO 30 sec Start
LBCO setting 
(11C)
22.0
LBCO setting 
(11C)
44.0
27 Save/Restore Setup Menu
See 
 for details.
27A Push INV now to save 
Settings
Push INV now to save Settings
27B Push GEN to restore settings
Push GEN to restore settings
27C Push GEN for Factory 
Defaults
PUSH GEN for Factory Defaults
Table B-7 Advanced Setup Default and User Settings for the Sine Wave Plus 5548 Model
Advanced Setup Menus
Sine Wave Plus
 5548
User Settings
Range/
Display
Default 
Settings
20 Silent Setup Menu
See 
 for details.
20A Refloat High Volts DC
32.2 to 67.8 
56.8
20B Refloat Low Volts DC
32.2 to 67.8 
50.0 
20C Float Done Amps AC
00 to 40 
10 
20D Must Float Time Min
00 to 255
05
21 Grid AC1 Usage Menu
See 
 for details.
21A Grid Usage SB BX 
SB BX
SB
21B Grid Usage Begin h:m
00:00 to 23:50
21:00
21C Grid Usage End h:m
00:00 to 23:50
21:00
22 Battery Xfer (BX) Menu
See 
 for details.
22A High Xfer (HBX) Vdc
32.2 to 67.8 
54.0 
Table B-6 Advanced Setup Default and User Settings for the Sine Wave Plus 4024 and 
4048 Models
Advanced Setup Menus
Sine Wave Plus
 4024
Sine Wave Plus
 4048
User 
Settings
Range/
Display
Default 
Settings
Range/
Display
Default 
Settings