Atlantis Land A03-HP2000 Manual De Usuario
TECHNICAL FEATURES
where solutions begin
Società Certificata ISO 9001:2000
UPS
MODEL
Power Rating
Power Rating
Power Rating
INPUT
OUTPUT
TRANSFER Line/Battery
DISPLAY & DIAGNOSTICS
Communication Port
Environmental Condition
SAFETY APPROVAL
DIMENSION (W*H*D cm)
Weight (N.W/ G.W) Kg
Environmental Condition
SAFETY APPROVAL
DIMENSION (W*H*D cm)
Weight (N.W/ G.W) Kg
LCD Display
LED Display
Beeping Alarm
Advanced Mode
VOLTAGE
RANGE
RANGE
Single Phase; 200/220/230/240V selectable by DIP Switch
±
23% of nominal input voltage
50Hz/60Hz Auto-Select as Input Hz
Normal Mode:
10% of rated voltage; Inverter mode:
3%
±
±
Pure Sine-Wave with THD 5% at linear load
Inverter mode: 50Hz or 60Hz
0.1Hz
±
Nearly Zero Transfer (<3ms)
With LCD & LED Display
DB9 port with TRUE RS232 serial signal plus dry contact signals
0-37°C; 0-90% Non Condensing Humidity
CE/UL
Normal, AC Input High, AC Input Low, On Battery,
Battery Low, Battery Bad, Overload, Fault, Phase error,
Ground Fault
Utility Voltage, Ouput Voltage, Output Hz, Load%,
UPS Temperature, Battery Voltage, Runtime Timer(HH:MM)
Battery Low, Battery Bad, Overload, Fault, Phase error,
Ground Fault
Utility Voltage, Ouput Voltage, Output Hz, Load%,
UPS Temperature, Battery Voltage, Runtime Timer(HH:MM)
Green=Normal, Amber=Warning, Red=Critical
LCD shows detalis in respect to the lighting indication of LED
LCD shows detalis in respect to the lighting indication of LED
Overload, Fault, High Temperature, Battery On, Battery Low,
Battery Bad, Over/Under Voltage, Frequency Error
Battery Bad, Over/Under Voltage, Frequency Error
Self-diagnostic; Direct Time-based readout of battery
remained runtime
remained runtime
Status:
Data:
8-12 min
Sealed Maintenance Free Lead Acid VRLA Type
Switch to Battery Output whrn the Utility over regulation range
Current-limiting & NFB (No Fuse Breaker) protection
for both Utility & Battery mode
for both Utility & Battery mode
Two stages, no battery drain after cut-off
Full time suppression
Meet with IEEE 587 cat. A&B Standard
RJ11 / RJ45
960 Joules instantaneous response
Better than 45dB @1Mhz for Normal/Common mode
EN50991-1
4*IEC(Battery Power Supply) + 1*Schuko
RS232(DB9)
Hz
VOLTAGE
WAVEFORM
Hz
VOLTAGE
WAVEFORM
Hz
Half-load runtime
Capacity
Quantity
Recharge Time
Type
Capacity
Quantity
Recharge Time
Type
Overload &
Shot Circuit
Shot Circuit
Low Battery
EMI/RFI
Surge Protection
Modem/Network
Energy Rating
Attenuation
Noise Filtering
EMI/RFI
Surge Protection
Modem/Network
Energy Rating
Attenuation
Noise Filtering
Output
Computer
Computer
BATTERY
PROTECTION
A03-HP1000 A03-HP1500 A03-HP2000 A03-HP3000
1000 VA
600 W
9Ah
7Ah
7Ah
7Ah
2
3
4
6
<8hrs
<5hrs
<2hrs
<2hrs
1500 VA
900 W
2000 VA
1200 W
3000 VA
1800 W
Over/Under Volt.
17*24*37
14/16
22/24
26/28
34/36
CONNECTIONS
HOST POWER Series
SineWave Line-Interactive Technology
ATLANTIS LAND S.p.A.
via De Gasperi, 122 - 20017 Mazzo di Rho (MI)
Tel. 02 9390.6085 - Fax 02 9390.6161 -
www.atlantis-land.com - info@atlantis-land.com