Panasonic PT-EW530U Manual De Usuario

Descargar
Página de 118
Network
78
 - ENGLISH
Settings
Error information page 
 
J
If [Error (Detail)] is displayed in the self-diagnosis information display column on the [Projector status] screen, 
click the part to display the details of the error.
Depending on the nature of the error, the projector may be placed in the standby mode for its own protection.
• 
                  
When [FAILED] has appeared for an item
Parameter
Description
MAIN CPU BUS
Trouble has occurred in the microcomputer circuitry. Consult your dealer.
FAN
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
INTAKE AIR TEMPERATURE
Intake air temperature is high. It could be because it is used in an environment of high 
temperature such as close to a heating device, etc., the air intake is blocked, or the air 
filter is clogged.
AROUND LAMP TEMPERATURE
The temperature around the lamp is too high. Exhaust may be blocked, or [Fan control] 
mode may be set wrong. See [Fan control] of the Functional Manual. (
Æ
page 66)
OPTICS MODULE TEMPERATURE
Optics module temperature is high. The exhaust air port maybe blocked or the air filter 
is clogged.
LAMP REMAIN TIME
The lamp runtime has exceeded the prescribed cumulative time, and it is now time to 
replace the lamp.
LAMP STATUS
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
APERTURE(CONTRAST-SHUTTER)
Trouble has occurred in the contrast shutter circuitry. Consult your dealer.
SHUTTER
There is a problem with shutter.
AIR FILTER
There is a problem with the air filter unit.
FILTER UNIT
The air filter unit is not installed.
Network status page
 
J
 Displays the current configuration information of the network.
Displays the configuration details of wired LAN.
OK:
      Normal operation
FAILED :     Occurrence of trouble
WARNING: Warning