Chapter 4 Settings — [PROJECTOR SETUP] menu
ENGLISH - 109
[COOLING CONDITION]
Change the fan control depending on the direction of projection.
Set [COOLING CONDITION] according to the projection direction, but set it to [AUTO] normally. Using the projector with incorrect setting may
Set [COOLING CONDITION] according to the projection direction, but set it to [AUTO] normally. Using the projector with incorrect setting may
shorten the life of the lamp.
:
30°
30°
30°
30°
30°
30°
[VERTICAL UP SETTING]
[FLOOR SETTING]
[CEILING SETTING]
[VERTICAL DOWN SETTING]
Projection direction
1) Press as to select [COOLING CONDITION].
2) Press the <ENTER> button.
2) Press the <ENTER> button.
f
The
[COOLING CONDITION] screen is displayed.
3) Press as to select a cooling condition.
f
When [AUTO] is selected, the cooling conditions of [FLOOR SETTING], [CEILING SETTING], [VERTICAL UP SETTING], and
[VERTICAL DOWN SETTING] are set automatically.
You can check the setting from [COOLING CONDITION] on the
You can check the setting from [COOLING CONDITION] on the
[STATUS] screen.
4) Press the <ENTER> button.
5) When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
5) When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
Note
f
This item cannot be set when using the optional Replacement lamp unit (for portrait mode) (Model No.: ET-LAD320P (1 pc), ET-LAD320PW
(2 pcs)). (Setting is fixed to [PORTRAIT SETTING].)
[HIGH ALTITUDE MODE]
Set to [ON] when using the projector at high altitudes between 1 400 m (4 593') or higher and lower than 2 700 m (8 858') above sea level.
1) Press as to select [HIGH ALTITUDE MODE].
2) Press qw to switch the item.
2) Press qw to switch the item.
[OFF]
When using at a location lower than 1 400 m (4 593') above sea level
[ON]
When using at high altitudes (1 400 m (4 593') or higher and lower than 2 700 m (8 858') above sea
level)
3) When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
Note
f
The speed of the fan increases and the operation sound becomes louder when set to [ON].
f
This item cannot be set when using the optional Smoke cut filter (Model No.: ET-SFD320). (Setting is fixed to [OFF].) Use it at elevations
lower than 1 400 m (4 593') above sea level.
[LAMP SELECT]
Select the lamp to be turned on from the two built-in luminous lamps according to the use conditions or purposes.
1) Press as to select [LAMP SELECT].
2) Press qw to switch the item.
2) Press qw to switch the item.
[DUAL]
Two lamps will light.
[SINGLE]
One lamp will light. (The lamp with shorter runtime will automatically light.)
[LAMP1]
Lamp 1 will light.
[LAMP2]
Lamp 2 will light.