5. ELECTRICAL CONNECTION
WARNING
1. Electrical connection must be made in accordance with the instructions on
a “WARNING” tag, provided with the pig tail leads in the Junction Box.
2. This icemaker requires a ground that meets the national and local electri-
cal code requirements.  To prevent possible electrical shock to individuals
or extensive damage to the equipment, install a proper ground wire to the
icemaker.
• The white lead must be connected to the neutral conductor of the power source.  Miswiring
results in severe damage to the icemaker.  See Fig. 3.
• This icemaker must have a separate power supply or receptacle of proper capacity.  See
the Nameplate.
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
• Usually an electrical permit and services of a licensed electrician are required.
WARNING
ELECTRICAL CONNECTION
The white lead must be connected
to the neutral conductor of
the power source.
Miswiring results in severe
damage to the icemaker.
(See Fig. below.)
Fig.3