DMC-1400  Series Command Reference IL 
● 107   
IL  
FUNCTION:  Integrator Limit 
DESCRIPTION: 
The IL command limits the effect of the integrator function in the filter to a certain voltage.  
For example, IL 2 limits the output of the integrator to the +/-2 Volt range. 
A negative parameter also freezes the effect of the integrator during the move.  For example, 
IL -3 limits the integrator output to +/-3V. If, at the start of the motion, the integrator 
output is 1.6 Volts, that level will be maintained through the move.  Note, however, that 
the KD and KP terms remain active in any case. 
ARGUMENTS:  IL n 
where  
 n is a number in the range 0 to 9.9988 Volts with a resolution of .0003. 
 “?” returns the value of the integrator limit 
USAGE: 
While Moving 
Yes 
Default Value 
9.9982 
In a Program 
Yes 
Default Format 
1.4 
Command Line 
Yes 
 
 
Can be Interrogated 
Yes 
 
 
Used as an Operand 
Yes 
 
 
Controller Usage                ALL  
OPERAND USAGE: 
 _IL contains the value of the integrator limit. 
RELATED COMMANDS: 
Integrator 
EXAMPLES: 
KI 2 
Integrator constants 
IL 3 
Integrator limits 
IL ? 
Returns the limit 