152 ● OP 
 
 
 
 
 
 
   DMC-1400 Series Command Reference 
OP     
 
 
 
 
FUNCTION:  Output Port 
DESCRIPTION: 
The OP command sends data to the output ports of the controller.  You can use the output port 
to control external switches and relays.   
ARGUMENTS (DMC-1410/1411/1412/1414/1417):  OP m,n  
where  
m is an integer in the range 0 to 7 and is the decimal representation of the 3 output bits.  
n is an integer in the range 1 to 3 decimal and is used to specify the number of bits effected 
starting with the LSB.  For example, if n=2, only outputs 1 and 2 will be changed by OP 
m.  If the n parameter is not specified, all bits will be changed. 
ARGUMENTS (DMC-1415/1416/1425):  OP m,a,b,c,d 
where  
m is an integer in the range 0 to 7 and is the decimal representation of the general output bits.   
a,b,c,d represent the extended I/O in consecutive groups of 16 bits, (values from 0 to 65535).  
Arguments that are given for I/O points which are configured as inputs will be ignored.  
The following table describes the arguments used to set the state of outputs. 
 
Arguments  
Blocks  
Bits 
Description  
1-3 
General Outputs  
2,3 
17-32 
Extended I/O  
b 4,5 
33-48 
Extended 
I/O 
c 6,7 
49-64 
Extended 
I/O 
d 8,9 
65-80 
Extended 
I/O 
n = ? returns the value of the argument, where n is any of the above arguments. 
USAGE: 
 
 
  DEFAULTS: 
While Moving 
Yes 
Default Value 
In a Program 
Yes 
Default Format 
3.0 
Command Line 
Yes 
 
 
Can be Interrogated 
Yes 
 
 
Used as an Operand 
Yes 
 
 
Controller Usage 
ALL  
OPERAND USAGE (DMC-1410/1411/1412/1414/1417): 
 _OP contains the status of the outputs. 
OPERAND USAGE (DMC-1415/1416/1425): 
_OP0 contains the value of the first argument, m 
_OP1 contains the value of the first argument, a 
_OP2 contains the value of the first argument, b 
_OP3 contains the value of the first argument, c 
_OP4 contains the value of the first argument, d 
RELATED COMMANDS: 
Set output bit 
Clear output bit 
Output Byte