Galil DMC-1400 Manual De Usuario

Descargar
Página de 235
DMC-1400  Series Command Reference AC 
● 15   
AC  
FUNCTION:  Acceleration 
DESCRIPTION: 
The Acceleration (AC) command sets the linear acceleration rate for independent moves, such 
as PR, PA and JG moves.  The parameters input will be rounded down to the nearest 
factor of 1024. The units of the parameters are counts per second squared.  The 
acceleration rate may be changed during motion.  The DC command is used to specify 
the deceleration rate. 
ARGUMENTS:  AC n 
where  
n is an unsigned number in the range in the range 1024 to 67107840  
“?” returns the acceleration value 
USAGE:     
While Moving 
Yes 
Default Value 
256000 
In a Program 
Yes 
Default Format 
8.0 
Command Line 
Yes 
 
 
Can be Interrogated 
Yes 
 
 
Used as an Operand 
Yes 
 
 
Controller Usage 
ALL 
OPERAND USAGE: 
_ACx contains the value of acceleration. 
RELATED COMMANDS: 
Specifies deceleration rate. 
Feedforward Acceleration. 
Smoothing constant  
EXAMPLES: 
AC 150000 
Set acceleration to 150000 
AC ? 
Request the current Acceleration setting 
0149504 
Return Acceleration   
(resolution, 1024) 
V=_AC 
Assigns the current acceleration setting to the variable V 
 
HINTS:  Specify realistic acceleration rates based on your physical system such as motor torque 
rating, loads, and amplifier current rating.  Specifying an excessive acceleration will cause large 
following error during acceleration and the motor will not follow the commanded profile.  The 
acceleration feedforward command FA will help minimize the error.