Galil DMC-1400 Manual De Usuario

Descargar
Página de 235
84 ● EP   
 
 
 
 
 
   DMC-1400 Series Command Reference 
EP  
FUNCTION:  Cam table master interval and phase shift 
DESCRIPTION: 
The EP command defines the ECAM table master interval and phase shift.  The interval m is 
the difference in master position between table entries.  The phase shift n instantaneously 
moves the graph of slave position versus master position left (negative) or right (positive) 
and is used to make on-the-fly corrections to the slaves.  Up to 257 points may be 
specified. 
ARGUMENTS:  EP  m,n   
where  
m is the master interval and is a positive integer in the range between 1 and 32,767 master 
counts.  m cannot be changed while ECAM is running. 
M = ?   Returns the value of the interval m. 
n is the phase shift and is an integer between -2,147,483,648 and 2,147,483,647 master 
counts.  m can be changed while ECAM is running. 
USAGE: 
While Moving 
Yes 
Default Value 
256,0 
In a Program 
Yes 
Default Format   
Command Line 
Yes 
 
 
Can be Interrogated 
Yes 
 
 
Used as an Operand 
Yes (m only) 
 
 
Controller Usage                ALL  
OPERAND USAGE: 
_EP contains the value of the interval m. 
RELATED COMMANDS: 
Enable Ecam 
Engage Ecam 
Specify Ecam Cycle 
Ecam quit 
Electronic CAM table 
EXAMPLES: 
EP 20 
Sets the cam master points to 0,20,40 . . . 
D =_EP 
Set the variable D equal to the ECAM internal master interval 
EP,100 
Phase shift all slaves by 100 master counts