Cabletron Systems HSIM-A6DP- Manual De Usuario

Descargar
Página de 100
Chapter 3: Local Management
3-14
HSIM-A6DP User’s Guide
3.7.3
Modifying an Entry (PVC)
To modify an existing entry (PVC), perform the following steps:
1.
Use the arrow keys to highlight the VPI field, and enter the new VPI 
value.
2.
Use the arrow keys to highlight the VCI field and enter the new VCI 
value; acceptable values are 32 through 1020.
3.
Use the arrow keys to highlight the Encapsulation Type field and 
press the SPACE bar until the desired Encapsulation Type appears.
4.
Use the arrow keys to select the ADD/MODIFY command.
5.
Press ENTER. The “ENTRY DELETED” then “ENTRY ADDED” 
messages appear at the top of the screen indicating that Local 
Management has modified the PVC.
3.7.4
Deleting an Entry (PVC)
To delete an entry (PVC), perform the following steps:
1.
Use the arrow keys to highlight the VPI field and enter the VPI of the 
PVC that you want to delete.
2.
Use the arrow keys to highlight the VCI field and enter the VCI of the 
PVC that you want to delete.
3.
Use the arrow keys to highlight the DELETE command.
4.
Press ENTER. The “ENTRY DELETED” message appears at the top 
of the screen indicating that Local Management has deleted the PVC.
NOTE
The DELETE command appears only if a valid VPI and VCI 
have been entered in their respective fields.