Chapter 3: Local Management
3-20
HSIM-A6DP User’s Guide
3.8.7
Setting the Periodic Test Status Field
To enable or disable the Periodic test status feature, perform the following 
steps:
1.
Use the arrow keys to highlight the Periodic test status field.
2.
Press the SPACE bar to toggle between the choices until the desired 
mode displays ([Enabled] or [Disabled]).
3.
Use the arrow keys to highlight the SAVE command at the bottom of 
the screen and press ENTER. The changes are saved to memory.
3.8.8
Setting the Periodic Test Time
To change the Periodic test time field from the default value of 01:00.00 
(1:00 A.M.), perform the following steps:
1.
Use the arrow keys to highlight the Periodic test time field.
2.
Enter the time in a 24-hour format, HH:MM.SS.
3.
Press ENTER to set the test time entered in the Periodic test time field.
4.
Use the arrow keys to highlight the SAVE command at the bottom of 
the screen and press ENTER.
5.
If the time entered is a valid format, the Event Message Line at the top 
of the screen displays “SAVED OK”. If the entry is not valid, Local 
Management does not alter the current value and refreshes the Periodic 
test time field with the previous value.
NOTE
When entering the time in the Periodic test time field, 
separators between hours, minutes, and seconds must be 
added. For example, to set the Periodic test time to 12:00 P.M. 
(Noon), type “24:00.00” in the Periodic test time field.