Chapter 3: Local Management
3-32
HSIM-A6DP User’s Guide
8.
Enter the LES ATM Address in the field. Ensure that a valid ATM 
address is used If there is more than one LECS present on the network, 
and a specific LECS is desired for this LEC, perform the substeps that 
follow.
a.
Use the arrow keys to highlight the LECS ATM Address field.
b.
Enter the LECS ATM Address in the field. Ensure that a valid 
ATM address is used.
9.
Use the arrow keys to highlight the ADD LEC command at the bottom 
of the screen and press ENTER. The manually configured LEC is now 
entered into the HSIM-A6DP LEC Index.
3.11.5
Modifying an Existing LEC
To modify a LEC that has already been created, perform the following 
steps:
1.
Use the arrow keys to highlight the MODIFY MODE command and 
press ENTER.
1.
Use the arrow keys to highlight the LEC Index field.
2.
Enter the LEC Index of the LEC that will be modified.
3.
Use the arrow keys to highlight the Configure LEC field.
4.
Use the SPACE bar to toggle between the options until the desired 
mode displays.
5.
If the LEC will be modified manually, perform the following substeps:
a.
Use the arrow keys to highlight the ELAN Name field. Enter a 
name for the LEC that is no more than 32 characters in length. 
b.
Use the arrow keys to highlight the MAX MTU Size field.
c.
Use the SPACE bar to toggle between the options until the desired 
MTU size displays.
d.
Use the arrow keys to highlight the LES ATM Address field.
e.
Enter the LES ATM Address in the field. Ensure that a valid ATM 
address is used.