Cabletron Systems HSIM-A6DP- Manual De Usuario

Descargar
Página de 100
Chapter 3: Local Management
3-46
HSIM-A6DP User’s Guide
UNI Q93b Status (Read-Only)
This is a read-only field that displays the current UNI Q93b status. If the 
HSIM-A6DP is connected to an ATM network, this field should read 
“Enabled”. If this field reads “Disabled” UNI did not start up correctly, 
and some UNI services may not be available. If this field remains in a 
disabled state, check that all appropriate UNI services in the ATM 
network have been configured properly.
UNI Version (Toggle)
This field displays the current version of UNI being used by the 
HSIM-A6DP. This field is modifiable if signaling is enabled manually by 
the user. In autoconfigure mode the HSIM-A6DP uses either UNI 3.0 or 
UNI 3.1, depending on the version of UNI being used by the ATM switch 
to which the HSIM-A6DP is connected.
SAVE (Command)
This command saves all changes to memory.
RESTART UNI (Command)
This command restarts UNI. For instructions on how to restart UNI, refer 
to 
RESTART ILMI (Command)
This command restarts the ILMI. For instructions on how to restart the 
ILMI refer to 
3.15.2
Changing the ILMI Status
To change the ILMI status from the default state of [Auto Configure 
Enabled] perform the following steps:
1.
Use the arrow keys to highlight the ILMI Status field.
2.
Use the SPACE bar until the option [Enabled] displays.
!
CAUTION
Before completing the following step, ensure that this caution is 
fully understood. By disabling the ILMI, ALL SVCs currently 
configured on the HSIM-A6DP will be lost.