General Configuration Screen
2M46-04R/2M46-04RDC User’s Guide
5-21
4.
Use the arrow keys to highlight the SAVE command, then press 
ENTER. The warning screen shown back in 
 displays.
5.
Use the arrow keys to highlight the YES command and press ENTER. 
The changes are saved and the device reboots.
5.7.3
Setting the Default Gateway
If the SNMP management station is located on a different IP subnet than 
the 2M46-04R, a default gateway must be specified. When an SNMP Trap 
is generated, the 2M46-04R sends the trap to the default gateway. To set 
the default gateway, perform the following steps:
1.
Use the arrow keys to highlight the Default Gateway field.
2.
Enter the IP address of the default gateway using the DDN format.
For example: 134.141.79.121
3.
Press ENTER. If the default gateway entered is a valid format, the 
cursor returns to the beginning of the Default Gateway field. If the 
entry is not valid, the Event Message Line displays “INVALID 
DEFAULT GATEWAY OR FORMAT ENTERED”. Local 
Management does not alter the current value, but it does refresh the 
Default Gateway field with the previous value.
4.
Use the arrow keys to highlight the SAVE command.
5.
Press ENTER. The Event Message Line at the top of the screen 
displays “SAVED OK”.
5.7.4
Setting the TFTP Gateway IP Address
If the network TFTP server is located on a different IP subnet than the 
2M46-04R, a gateway IP address should be specified. To set the TFTP 
gateway IP address, perform the following steps:
1.
Use the arrow keys to highlight the TFTP Gateway IP Addr field.
2.
Enter the IP address of the TFTP gateway using the DDN format.
For example: 134.141.80.122