Unpacking and Installing Your ELS10-26
2.3  INSTALLING THE ELS10-26
Rack-mounting an ELS10-26
Table 2-3 describes some general considerations you should be 
aware of before mounting a ELS10-26 in a rack assembly.
Table 2-3.   General Considerations for Mounting an ELS10-26
Consideration
Discussion
Temperature
Since the temperature within a rack assembly 
may be higher than the ambient room 
temperature, make sure the rack environment 
temperature is within the Operating 
Temperature range specified in Appendix A.
Air Flow
Make sure there is at least 2 inches (or more) 
on both sides of the ELS10-26 to allow for 
adequate air flow.
Mechanical Loading
Do not place equipment on top of a rack-
mounted ELS10-26.
Circuit Overloading
Make sure the power supply circuit to the 
rack assembly is not overloaded.
Grounding 
(Earthing)
Rack-mounted equipment should be 
grounded. In addition to the direct 
connections to the main power supplies, make 
sure all the other supply connections are also 
grounded.