Configuring Traps
3-3
Configuring the Trap Table
traps with a severity level equal to or greater than this severity setting will be 
forwarded to the associated management workstation. Each trap is assigned one 
of four severity levels:
Informational
Indicates an informational event (no action generally 
required) or a small conÞguration error. This is a Level 4 
severity.
Minor
Indicates a minor fault or trafÞc disturbance; 
recommended action typically involves clearing the fault 
at the Þrst suitable occasion. This is a Level 3 severity.
Major
Indicates a major fault or link alarm; corrective action 
should be taken as soon as possible. This is a Level 2 
severity.
Critical
Indicates a serious fault or error that requires immediate 
action. This is a Level 1 severity.
Configuring Traps
To add a trap table entry:
1.
In the IP Address field, enter the IP address of the workstation to which you 
wish to direct trap messages from the selected FRX or SmartSwitch 1800 
device. Be sure this is a workstation with some facility for accepting and 
displaying SNMP traps.
2.
In the Status field, click to either enable or disable your new entry. If you 
disable an entry, no traps will be sent to its designated workstation.
3.
Use the Severity Level field to select which traps you wish to send to the 
selected workstation: only those traps with severity levels equal to or 
exceeding the level assigned here will be forwarded to the selected 
workstation.
4.
Click on 
 to add your new entry.
To modify an existing entry:
1.
In the list box, click to select the entry you wish to modify. The selected entry 
will be highlighted. (Note that you can only modify one entry at a time.)
2.
Edit the IP AddressStatus, and/or Severity Level fields, as desired.
3.
Click on 
 to modify the selected entry.