Appendix B    Cabling Guidelines 
Kingston Technology Company 
KNE24TP/RS User’s Guide - Rev. A01 
Cable Wiring Standards 
There are two governmental agencies: the Electronic Industry Association 
(EIA) and the Telecommunications Industry Association (TIA), which set the 
standard for all cable wiring requirements for commercial buildings. 
With the advent of 100Mb/s networking products, it is best to use higher 
quality CAT 5 cables like Belden or Helix as well as CAT 5-compliant patch 
panels, patch cables, and connectors while following the EIA/TIA wiring 
standards.  100 
Ω UTP CAT 5 type cables use 4-pair UTP wiring. 
Refer to the illustrations below for 4-pair wiring using either T568A (Fig. B-4) 
or T568B (Fig. B-5) wiring standards. Both T568A and T568B wiring is 
compatible with 10BASE-T and 100BASE-TX and require no special 
configurations, but stick to one wiring standard. If your building is wired for 
T568A, any changes or additions must be done with the T568A wiring scheme. 
Mixing the T568A and T568B wiring schemes will not work. 
1 2 3 4 5 6 7 8
Pair 2
Pair 3 Pair 1 Pair 4
T568A
 
Fig. B-4.  4-Pair T568A Wiring 
1 2 3 4 5 6 7 8
Pair 3
Pair 2 Pair 1 Pair 4
T568B
 
Fig. B-5.  4-Pair T568B Wiring 
T568A 
Pairs 
Strand 
Solid 
T568B 
Pairs 
Strand 
Solid 
Pin 1 
Pair 3 
Blue 
White/Green 
Pin 1 
Pair 2 
Black 
White/Orange 
Pin 2 
Pair 3 
Orange 
Green/White 
Pin 2 
Pair 2 
Yellow 
Orange/White 
Pin 3 
Pair 2 
Black 
White/Orange 
Pin 3 
Pair 3 
Blue 
White/Green 
Pin 4 
Pair 1 
Red 
Blue/White 
Pin 4 
Pair 1 
Red 
Blue/White 
Pin 5 
Pair 1 
Green 
White/Blue 
Pin 5 
Pair 1 
Green 
White/Blue 
Pin 6 
Pair 2 
Yellow 
Orange/White 
Pin 6 
Pair 3 
Orange 
Green/White 
Pin 7 
Pair 4 
Brown 
White/Brown 
Pin 7 
Pair 4 
Brown 
White/Brown 
Pin 8 
Pair 4 
White 
Brown/White 
 
Pin 8 
Pair 4 
White 
Brown/White 
Table. B-6.  4-Pair T568A Wiring 