Kingston Technology KNS800/WG Manual De Usuario

Descargar
Página de 24
12
Appendix B    Cabling Guidelines
Kingston Technology Company                   KNS800/WG User’s Guide – Rev.B01
UTP Cable Wiring Standards
There are two governmental agencies: the Electronic Industry Association
(EIA) and the Telecommunications Industry Association (TIA), which set the
standard for all cable wiring requirements for commercial buildings.
With the advent of 100Mb/s networking products, it is best to use higher
quality CAT 5 cables like Belden or Helix as well as CAT 5-compliant patch
panels, patch cables, and connectors while following the EIA/TIA wiring
standards.  100 
Ω
 UTP CAT 5 type cables use 4-pair UTP wiring.
Refer to the illustrations below for 4-pair wiring using either T568A (Fig. B-1)
or T568B (Fig. B-2) wiring standards. Both T568A and T568B wiring is
compatible with 10BASE-T and 100BASE-TX and require no special
configurations, but for premise wiring, stick to one wiring standard. Mixing
T568A and T568B wiring schemes may cause or lead to potential problems.
     Fig. B-1  4-Pair T568A Wiring
Fig. B-2  4-Pair T568B Wiring
T568A
Pairs
Strand
Solid
T568B
Pairs
Strand
Solid
Pin 1
Pair 3
Blue
White/Green
Pin 1
Pair 2
Black
White/Orange
Pin 2
Pair 3
Orange
Green/White
Pin 2
Pair 2
Yellow
Orange/White
Pin 3
Pair 2
Black
White/Orange
Pin 3
Pair 3
Blue
White/Green
Pin 4
Pair 1
Red
Blue/White
Pin 4
Pair 1
Red
Blue/White
Pin 5
Pair 1
Green
White/Blue
Pin 5
Pair 1
Green
White/Blue
Pin 6
Pair 2
Yellow
Orange/White
Pin 6
Pair 3
Orange
Green/White
Pin 7
Pair 4
Brown
White/Brown
Pin 7
Pair 4
Brown
White/Brown
Pin 8
Pair 4
White
Brown/White
Pin 8
Pair 4
White
Brown/White
Table. B-4  4-Pair T568A Wiring
Table B-5  4-Pair T568B Wiring
1 2 3 4 5 6 7 8
Pair 2
Pair 3 Pair 1 Pair 4
T568A
1 2 3 4 5 6 7 8
Pair 3
Pair 2 Pair 1 Pair 4
T568B